| APLICATIONS

– Roofs and façades that require thermal and acoustic insulation

Categories: ,

Description

| TECHNICAL DATA:

Technical data
Model EPS 34 EPS 35 EPS 36 EPS 39 EPS 46
Declared thermal conductivity
λat 10ºC (W/m·K)
0,034   0,035 0,036 0,039 0,046
Minimum buckling resistance (kPa) 50 – BS50
Dimensional stability in normal
conditions and laboratory constants (%)
± 0,2 – DS(N)
Dimensional stability in specific
temperature and humidity conditions (%)
Dimensional variation ≤ 1%
Tolerances Length ±0,6% ó ± 3mm – L1
Width ±0,6% ó ± 3mm – W1
Thickness ±2 mm – TI
Rectangularity ±5 mm every 1000 mm – S1
Flatness ±10 mm – P3
                                                                                                       Thermal resistance (m2·K/W)
Thickness 30 0,65 0,75 0,80  0,85 0,85
40   0,85 1,00 1,10  1,10 1,15
50 1,05 1,25 1,35 1,40 1,45
60 1,30 1,50 1,65 1,70  1,75
70 1,50 1,75 1,90 2,00 2,05
80 1,70 2,05 2,20 2,25 2,35

| PROFILE ACOT: 

Poliestireno Expandido perfil