| PROFILE ACOT: 

Perfil Minionda DF-18-76

| TECHNICAL DATA:

Profile characteristics
Number of waves 14
Wave pitch 76 mm
Wave height 18 mm
Useful width 1026 mm (According to overlap)
Maximum lenght As per order
Technical data
Thickness Weight Momentof inercia 1 Resistance moment W Bending moment M
mm kg/m kg/m2 cm4 cm3 kg·m
0,5 5 4,87 1,71 1,95 27,29
0,6 6 5,85 2,05 2,33 32,56
0,7 7 6,82 2,39 2,70 37,74
0,8 8 7,80 2,74 3,06 42,92