| APLICATIONS

– Simple roofs and façades
– Sandwich roofs and façades
– Inner perforated roofs and façades that require acoustic insulation
– Deck type roofs
– Lost formwork
– Perforated façades that require lighting and ventilation
– False ceilings
– Renovation of roofs and façades

|DOWNLOADS

Data sheet

Declaration of Performace

 

Category:

Description

| PROFILE ACOT: 

Perfil Trapezoidal DF-40/250

|  TECHNICAL DATA:

Profile characteristics
Number of frets 5
Fret pitch 250 mm
Fret height 40 mm
Useful width 1000 mm
Maximum lenght As per order
Thickness Weight Momentof inertia I
mm kg/m kg/m2 cm4
0,5 5 5 13,01
0,6 6 6 15,48
0,7 7 7 17,97
0,8 8 8 20,43
Position A Roof Position B Façade
Thickness Resistance
moment W
Bending
moment M
Resistance
moment W
Bending
moment M
mm cm3 kg·m cm3 kg·m
0,5 4,23 59,27 3,86 54,04
0,6 5,04 70,56 4,69 65,66
0,7 5,78 80,92 5,74 80,36
0,8 6,62 92,68 6,46 90,44

RETURN TO PROFILE